What do EMI, EMC and RFI mean?
Vishay defines EMI, electromagnetic interference, as unwanted electrical energy in any form; the term is often used interchangeably with “noise”. RFI, radio-frequency interference, is an older and more restrictive term used interchangeably with EMI. [1]
EMC is not a disturbance but a property. According to TDK, it means that a device does not influence other devices through undesired emissions and is not influenced by emissions from other devices. TDK also quotes the definition in the European EMC directive 2014/30/EU: the ability of equipment to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances to other equipment. [2]
That definition has two sides. Murata calls stopping a device from producing noise an emission countermeasure, and making the receiving device work without errors even when noise arrives an immunity countermeasure; together they are EMC countermeasures. [3]
At which frequencies are conducted and radiated emissions measured?
Interference travels along conductors (conducted) or as a field (radiated). According to TDK, at low frequencies interference can be assumed to spread only along conductive structures, and in the MHz range increasingly by fields and electromagnetic radiation. [2]
The measurement ranges follow this split. TDK states that limit requirements for conducted emission are usually given from 150 kHz to 30 MHz, and for some products also from 9 kHz to 150 kHz. Radiated interference is most often measured at a distance of 10 m or 3 m, from 30 MHz to 1 GHz or even higher. [2] The range and limit that apply depend on the standard the product falls under.
Why do common-mode and differential-mode noise need different components?
Conducted interference has two parts. A differential-mode interference current flows out on one line and back on the other, just as the line current does. A common-mode interference current, produced through parasitic capacitances, flows in the same direction along both lines and returns to the source through ground. [2]
According to TDK, conducted interference up to several hundred kHz is mainly differential mode, while common-mode interference becomes dominant above several MHz. [2] Because the current paths differ, so do the components:
- For differential mode: X capacitors, connected between phase and neutral or between two phases, and series inductors (differential-mode chokes). [2]
- For common mode: Y capacitors, connected between phase or neutral and ground, and current-compensated (common-mode) chokes. [2]
A common-mode choke separates the two modes by its winding direction. Murata explains that the fluxes of common-mode currents point the same way and reinforce each other, while those of differential-mode currents cancel. The coil therefore acts as an inductor only for common mode, and its core does not saturate under a large line current. [4]
What is inside a mains EMI filter?
TDK defines an EMC filter as a circuit of inductors, capacitors and resistors that limits interference in power networks. It is virtually always a low-pass filter: it passes the usable frequency (typically DC to 60 Hz) and weakens interference frequencies. The key components are typically X capacitors, differential-mode chokes, Y capacitors, current-compensated chokes and discharge resistors. [2]
EMC filters act predominantly on conducted interference. [2] For the selection steps, see the single-phase EMI filter selection guide.
Where does a cable ferrite help, and where does it not?
According to Murata, if a cable is connected to a circuit, common-mode current also flows through the cable and is released as radio waves; the cable behaves as an antenna. [4] A cable ferrite is used against this current. Würth Elektronik describes cable ferrites as sleeves or rings that create a resistive and inductive series impedance; placed over a cable, such a sleeve can reduce the radiation of high-frequency energy from it. [5]
The same document shows the limits:
- The impedance depends on frequency and on the material; the interference frequency range and the material properties must match. [5]
- In Würth's two-wire measurement, passing both wires through the ferrite gave no attenuation of differential-mode interference between 100 kHz and 50 MHz. [5]
- If a high direct current flows through the cable, a high permeability quickly saturates the sleeve; routing the return conductor through the sleeve as well almost completely compensates for this. [5]
For choosing a part, see the cable ferrite selection and flat cable ferrite selection guides.
What is measured in an EMC test? Does one component make a product compliant?
TDK notes that EMC measurements distinguish between emission testing and susceptibility testing. Conducted emission is measured with a receiver through a line impedance stabilisation network (LISN) at the supply input; radiated emission in a full or semi-anechoic chamber. Examples of susceptibility tests are electrostatic discharge (ESD), fast transients (burst) and surge voltages. [2]
When placing a device on the market, the manufacturer must use a declaration of conformity to verify that it meets the applicable EMC directives, and EMC measurements are usually needed for this. [2] Compatibility is therefore demonstrated by measuring the finished product. A filter or a ferrite is one measure that contributes to that result; on its own it does not make a product compliant.
Asking Artek about an EMI filter or a cable ferrite
Share the following in your request:
- The type of problem (conducted or radiated) and the frequency range, if known.
- For a filter: mains voltage, line current and number of phases.
- For a cable ferrite: outer diameter of the cable, or the width of the flat cable.
- Required quantity.
The Artek catalog lists power/EMI filters (including the entry “6 A EMI Filter”), the clip-on round cable ferrites “Yuvarlak Plastik Kablo Çekirdekleri” from 6mm to 14.5mm, and the flat cable ferrite “Yassı Parazit Önleyici Flex Kablo Filtresi”. Browse power and EMI filters in the catalog or send Artek your request.
Frequently asked questions
What is the difference between EMI and EMC?
EMI is the interference itself, that is, unwanted electrical energy. EMC is the property of a device that neither disturbs its surroundings through undesired emissions nor is disturbed by the emissions of other devices. [1][2]
How is an EMC test carried out?
Emission and susceptibility are tested separately. According to TDK, conducted emission is usually measured from 150 kHz to 30 MHz through a line impedance stabilisation network, and radiated emission from 30 MHz upwards in an anechoic room. [2]
Will fitting a cable ferrite make a product pass an EMC test?
Not by itself. A cable ferrite adds a series impedance against the interference current, but that impedance depends on frequency and material; the result is confirmed only by measuring the finished product. [5]
Technical sources
- [1] Vishay: Inductor and magnetic product terminology (document 34053).
- [2] TDK Electronics: EMC filters, general technical information.
- [3] Murata: Basics of noise countermeasures, Lesson 1 — What is an EMI filter?.
- [4] Murata: Basics of noise countermeasures, Lesson 6 — Common mode choke coils.
- [5] Würth Elektronik: ANP115 — Cable ferrites and nanocrystalline sleeves for automotive applications.